Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rocket domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/sachirx7/steeltube.co.in/wp-includes/functions.php on line 6114

Warning: Cannot modify header information - headers already sent by (output started at /home/sachirx7/steeltube.co.in/wp-includes/functions.php:6114) in /home/sachirx7/steeltube.co.in/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home/sachirx7/steeltube.co.in/wp-includes/functions.php:6114) in /home/sachirx7/steeltube.co.in/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home/sachirx7/steeltube.co.in/wp-includes/functions.php:6114) in /home/sachirx7/steeltube.co.in/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home/sachirx7/steeltube.co.in/wp-includes/functions.php:6114) in /home/sachirx7/steeltube.co.in/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home/sachirx7/steeltube.co.in/wp-includes/functions.php:6114) in /home/sachirx7/steeltube.co.in/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home/sachirx7/steeltube.co.in/wp-includes/functions.php:6114) in /home/sachirx7/steeltube.co.in/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home/sachirx7/steeltube.co.in/wp-includes/functions.php:6114) in /home/sachirx7/steeltube.co.in/wp-includes/rest-api/class-wp-rest-server.php on line 1893

Warning: Cannot modify header information - headers already sent by (output started at /home/sachirx7/steeltube.co.in/wp-includes/functions.php:6114) in /home/sachirx7/steeltube.co.in/wp-includes/rest-api/class-wp-rest-server.php on line 1893
{"id":7091,"date":"2021-11-20T11:03:06","date_gmt":"2021-11-20T05:33:06","guid":{"rendered":"https:\/\/steeltube.co.in\/?page_id=7091"},"modified":"2024-04-16T17:08:35","modified_gmt":"2024-04-16T11:38:35","slug":"monel-alloy-k500-tube-to-male-fittings","status":"publish","type":"page","link":"https:\/\/steeltube.co.in\/monel-alloy-k500-tube-to-male-fittings\/","title":{"rendered":"Monel Alloy K500 Tube to Male Fittings Manufacturers In India"},"content":{"rendered":"

Monel Alloy K500 Tube to Male Fittings Manufacturers In India<\/strong><\/span><\/h1>\n

Sachiya Steel International<\/strong> <\/a>is one of the Leading Manufacturer And Exporter Of High Quality Monel Alloy K500 Tube to Male Fittings,<\/strong> which are mass \u2013 produced under the management of our knowledgeable specialists. The finest machinability for this Monel K500 Tube Fittings is in the annealed form. The corrosion resistance of Monel K500 Compression Fittings is considerably corresponding to that of alloy K500, apart from that, when in the age \u2013 hard-bitten form, it has a superior propensity to SCC in some atmospheres.<\/span><\/p>\n

\"Monel<\/span><\/p>\n

Monel K500 Male Connector Fittings\u00a0is generally used in Chemical Process Industry: such as in procedures connecting organic acids, dry chlorine and caustic soda, manufacture of chlorinated plastics, and so on. Monel K500 Ferrule Fittings (UNS N05500) has resistant to a sour \u2013 gas atmosphere. Meanwhile, these\u00a0Monel K500 Double Ferrule Fittings are also being offered in different sizes and shapes to our customers. The high chromium content gives Alloy K500 Tube Fittings excellent resistance to aqueous corrosion by oxidizing acids (especially nitric acid) and salts and to suffixation at high \u2013 temperatures.<\/span><\/p>\n

Alloy K500 Compression Fittings has a superior stress cracking resistance than Monel K500 in steam generation nuclear reactors for piping, separators and weldments. The properties of Alloy K500 Male Connector Fittings are useful for various applications involving nitric or nitric \/ hydrofluoric acid solutions. These impact strengths (averages from several tests) in\u00a0Alloy K500 Ferrule Fittings\u00a0were generated using notch samples, which are machined from plates.<\/span><\/p>\n\n\n\n\n\n\n\n\n
\n

Monel Alloy K500 Tube to Male Fittings Specifications<\/span><\/h2>\n<\/td>\n<\/tr>\n

Specifications<\/strong><\/span><\/td>\n:<\/strong><\/span><\/td>\nASTM B366 ASME SB366<\/span><\/td>\n<\/tr>\n
Tube Size<\/strong><\/span><\/td>\n:<\/strong><\/span><\/td>\n6mm to 38mm to 1\/4\u2033 to 1 1\/2\u2033<\/span><\/td>\n<\/tr>\n
Thread
\n<\/strong><\/span><\/td>\n
:<\/strong><\/span><\/td>\nNPT, BSP, BSPT, UNF, ISO, SAE etc.<\/span><\/td>\n<\/tr>\n
Brass<\/strong><\/span><\/td>\n:<\/strong><\/span><\/td>\nASTM B16 ASTM B 453<\/span><\/td>\n<\/tr>\n
Pressure Rating<\/strong><\/span><\/td>\n:<\/strong><\/span><\/td>\n6000PSI for Monel, 300\/1000\/3000PSI for Brass<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Monel Alloy K500 Tube To Male Fittings Chemical Composition<\/strong><\/span><\/h3>\n
\n\n\n\n\n
Grade<\/strong><\/span><\/td>\nC<\/strong><\/span><\/td>\nMn<\/strong><\/span><\/td>\nSi<\/strong><\/span><\/td>\nS<\/strong><\/span><\/td>\nCu<\/strong><\/span><\/td>\nFe<\/strong><\/span><\/td>\nNi<\/strong><\/span><\/td>\n<\/tr>\n
Monel K500<\/strong><\/span><\/td>\n0.25 max<\/span><\/td>\n1.5 max<\/span><\/td>\n0.5 max<\/span><\/td>\n0.010 max<\/span><\/td>\n27.00 \u2013 33.00<\/span><\/td>\n0.5 \u2013 2<\/span><\/td>\n63.00 min<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

Monel K500 Tube To Male Fittings Mechanical Properties<\/strong><\/span><\/h3>\n
\n\n\n\n\n
Element<\/strong><\/span><\/td>\nDensity<\/strong><\/span><\/td>\nMelting Point<\/strong><\/span><\/td>\nTensile Strength<\/strong><\/span><\/td>\nYield Strength (0.2%Offset)<\/strong><\/span><\/td>\nElongation<\/strong><\/span><\/td>\n<\/tr>\n
Monel K500<\/strong><\/span><\/td>\n8.44 g\/cm3<\/span><\/td>\n1350 \u00b0C (2460 \u00b0F)<\/span><\/td>\nPsi \u2013 160000 , MPa \u2013 1100<\/span><\/td>\nPsi \u2013 115000 , MPa \u2013 790<\/span><\/td>\n20 %<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

Equivalent Grades for K500 Monel Ferrule Fitting Tube To Male Fittings<\/strong><\/span><\/h3>\n
\n\n\n\n\n
STANDARD<\/strong><\/span><\/td>\nWERKSTOFF NR.<\/strong><\/span><\/td>\nUNS<\/strong><\/span><\/td>\n<\/tr>\n
Monel K500<\/strong><\/span><\/td>\n2.4375<\/span><\/td>\nN05500<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

Alloy K500 Tube To Male Fittings Application Industries<\/strong><\/span><\/h3>\n