action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/sachirx7/steeltube.co.in/wp-includes/functions.php on line 6114Sachiya Steel International<\/strong><\/a> is pioneer Manufacture and Exporter of quality SMO 254 Tube to Female Pipes<\/strong>, which is commercially pure (99.6 %) wrought nickel. SMO 254 Tube Fittings is normally limited to service at temperatures below 600 Degree F. At higher temperatures,\u00a0SMO 254 Compression Fittings<\/strong>\u00a0can suffer from graphitization which can result in severely compromised properties. All hot working and cold working practices for SMO 254 Female Connector Fittings can be utilized when shaping this alloy.<\/span><\/p>\n Hot working temperatures should be between 1200 Degree F and 2250 Degree F in\u00a0SMO 254 Ferrule Fittings<\/strong>, with heavy forming to be performed at temperatures above 1600 Degree F. Annealing of\u00a0SMO 254 Double Ferrule Fittings<\/strong>\u00a0should be performed at a temperature between 1300 Degree F and 1600 Degree F. Care should be taken when choosing the anneal temperature and time at temperature for this can greatly influence the mechanical properties and structure of Alloy 254 Female Connector Fittings.<\/span><\/p>\n When operating temperatures in\u00a0Alloy 254 Compression Tube Fittings<\/strong>\u00a0are expected to exceed 600 Degree F, carbon content becomes critical. The lower carbon content of Alloy 254 Tube Fittings makes the material resistant to graphitization and therefore less subject to embrittlement.\u00a0Alloy 254 Compression Fittings<\/strong>\u00a0is approved for construction of pressure vessels and components under ASME Boiler and Pressure Vessel Code Section VIII, Division 1.\u00a0Alloy 254 Ferrule Fittings<\/strong>\u00a0has good mechanical properties and excellent resistance to many corrosive environments.<\/span><\/p>\n <\/p>\n\n\n
\n \n SMO 254 Tube to Female Pipes Specifications<\/span><\/h2>\n<\/td>\n<\/tr>\n
\n Specifications<\/strong><\/span><\/td>\n :<\/strong><\/span><\/td>\n ASTM A403 ASME SB 366<\/span><\/td>\n<\/tr>\n \n Size<\/strong><\/span><\/td>\n :<\/strong><\/span><\/td>\n OD -: 6mm to 38mm, Inch -: 1\/4\u2033 to 1 1\/2\u2033<\/span><\/td>\n<\/tr>\n \n Thread<\/strong><\/span><\/td>\n :<\/strong><\/span><\/td>\n NPT, BSP, BSPT, UNF, ISO, SAE etc.<\/span><\/td>\n<\/tr>\n \n Pressure Rating
\n<\/strong><\/span><\/td>\n:<\/strong><\/span><\/td>\n 3000 \u2013 4000 PSI<\/span><\/td>\n<\/tr>\n \n Applicable Temperature
\n<\/strong><\/span><\/td>\n:<\/strong><\/span><\/td>\n 150-400 C<\/span><\/td>\n<\/tr>\n \n Type
\n<\/strong><\/span><\/td>\n:<\/strong><\/span><\/td>\n Single Ferrule tube fitting, Double Ferrule tube fitting, Hydraulic tube fitting, Instrumentation tube fitting.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n SMO 254 Tube to Female Pipes Fitting Chemical Composition<\/strong><\/span><\/h3>\n
\n\n
\n SMO 254<\/strong><\/span><\/td>\n Ni<\/strong><\/span><\/td>\n C<\/strong><\/span><\/td>\n Mo<\/strong><\/span><\/td>\n Mn<\/strong><\/span><\/td>\n Si<\/strong><\/span><\/td>\n Fe<\/strong><\/span><\/td>\n Cu<\/strong><\/span><\/td>\n S<\/strong><\/span><\/td>\n P<\/strong><\/span><\/td>\n Cr<\/strong><\/span><\/td>\n<\/tr>\n \n 17.5<\/span>\u00a0\u2013\u00a018.5<\/span>
\n<\/span><\/td>\n0.02<\/span>\u00a0max<\/span><\/td>\n 6<\/span>\u00a0\u2013\u00a06<\/span>.5
\n<\/span><\/td>\n1 max<\/span><\/td>\n 0.8<\/span>\u00a0max<\/span><\/td>\n \u2013<\/span><\/td>\n 0.5<\/span>\u00a0\u2013 1<\/span><\/td>\n 0.01<\/span>\u00a0max<\/span><\/td>\n 0.03<\/span>\u00a0max<\/span><\/td>\n 19.5<\/span>\u00a0\u2013\u00a020.5<\/span><\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n SMO 254 Tube to Female Pipes Fitting Mechanical Properties<\/strong><\/span><\/h3>\n
\n\n
\n Density<\/strong><\/span><\/td>\n Melting Point<\/strong><\/span><\/td>\n Yield Strength (0.2%Offset)<\/strong><\/span><\/td>\n Tensile Strength<\/strong><\/span><\/td>\n Elongation<\/strong><\/span><\/td>\n<\/tr>\n \n 8.0 g\/cm3<\/span><\/span><\/td>\n 1320-1390 \u2103<\/span><\/span><\/td>\n 300<\/span><\/span><\/td>\n 650<\/span><\/span><\/td>\n 35 %<\/span><\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n Equivalent Grades for 254 SMO Tube to Female Pipes Fitting<\/strong><\/span><\/h3>\n
\n\n
\n STANDARD<\/strong><\/span><\/td>\n UNS<\/strong><\/span><\/td>\n WERKSTOFF NR.<\/strong><\/span><\/td>\n AFNOR<\/strong><\/span><\/td>\n EN<\/strong><\/span><\/td>\n JIS<\/strong><\/span><\/td>\n SIS<\/strong><\/span><\/td>\n GOST<\/strong><\/span><\/td>\n<\/tr>\n \n SMO 254<\/strong><\/span><\/td>\n S31254<\/span><\/td>\n 1.4547<\/span><\/td>\n Z1 CNDU 20.18.06Az<\/span><\/td>\n X1CrNiMoCuN20-18-7<\/span><\/td>\n \u2013<\/span><\/td>\n 2378<\/span><\/td>\n \u2013<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n SMO 254 Tube to Female Pipes Application Industries<\/strong><\/span><\/h3>\n
\n
SMO 254 Tube to Female Pipes Test Certificates<\/strong><\/span><\/h3>\n